Basic UPS Circuit
The above diagram is a basic Uninterupted Power Supply (UPS) circuit. This is a very simple and inexpensive circuit.
This circuit can be adapted/modified for other regulated and unregulated voltages by using different regulators and batteries. For a 15 Volt regulated supply, you may apply two 12V batteries connected in series (it will become 24V) including a 7815 regulator (will be 15V stabilized voltage output). There is a lot of flexibility in this circuit.
The capacity to keep up the regulated supply with no electrical supply relies on the load taken from the UPS and also the Ampere hour capacity of the battery. In the event that you were utilizing a 7A/h 12V battery and load from the 5V regulator was 0.5 Amp (and no load from the unregulated supply) then the regulated supply would be maintained for around 14 hours. Greater A/h capacity batterieswould give a more drawn out standby time, and the other way around.
Comments
Post a Comment