Simple Gas Smoke Detector Circuit Diagram

Image
 This is the Simple Gas Smoke Detector Circuit Diagram. In the presence of smoke or gas, the ac output voltage increases and becomes rectified, filtered and zener-diode coupled (D2 for thresholding) to sensitivity control R3. Under no gas condition, the output equals approximately 0 V (high). When gas is present, the output will be a negative value (low) sufficient to overcome the threshold of MeMOS gate 2 and D2.  Simple Gas Smoke Detector Circuit Diagram   The circuit shown uses a TGS 308 sensor, a generalpurpose gas detector that is not sensitive to smoke or carbon monoxide. If smoke is the primary element to be detected, use the TGS 202 sensor. The two sensors are basically identical; the main differences lie in the heater voltage and the required warm up time delay. The TGS requires a 1.2 V heater and a 2 minute delay, whereas the TGS 202 requires 1.5 V and 5 minutes, respectively.  The system uses a MeMOS gated oscillator directly interfacing with a triac-contr...